°ÄÃÅÁùºÏ²Ê¸ßÊÖ

Lettres d'information

Choisissez ce que vous souhaitez recevoir :

Merci de renseigner votre adresse de messagerie électronique :

@

Votre adresse email ne sera utilisée que dans le cadre de campagnes d'information °ÄÃÅÁùºÏ²Ê¸ßÊÖ Organization auxquelles vous êtes abonné. °ÄÃÅÁùºÏ²Ê¸ßÊÖ Organization ne communiquera jamais votre adresse email et autres informations personnelles à quiconque ou dans le cadre d'informations commerciales.

Si vous changez d'avis, il vous est possible de vous désinscrire en cliquant sur le lien 'unsubscribe' visible dans vos emails provenant d'°ÄÃÅÁùºÏ²Ê¸ßÊÖ Organization.

Pour plus d'information, veuillez consulter notre Politique de confidentialité.

Actu & Médias

Links

Of Interest

See archived articles

Conferences

  • 19 Oct - 25 Oct, 2024 Cracow, Poland
  • 21 Oct - 23 Oct, 2024 Rome, Italy
  • 21 Oct - 24 Oct, 2024 Oxford, United Kingdom
  • 28 Oct - 30 Oct, 2024 Mexico City, Mexico

Pour les actualités en français, voir la page Actus & Médias.

A strong contribution to neutral beam development

The Indian Test Facility in Ahmedabad, India: 600 m² for the full characterization of the diagnostic neutral beam. Experimentation should begin in January 2015. Image: °ÄÃÅÁùºÏ²Ê¸ßÊÖ India (Click to view larger version...)
The Indian Test Facility in Ahmedabad, India: 600 m² for the full characterization of the diagnostic neutral beam. Experimentation should begin in January 2015. Image: °ÄÃÅÁùºÏ²Ê¸ßÊÖ India
The diagnostic neutral beam—one of °ÄÃÅÁùºÏ²Ê¸ßÊÖ Tokamak's three neutral beams—is about to enjoy some time in the spotlight. Work begun in 2009 on the civil construction works of the Indian Test Facility in Ahmedabad is now completed: here, the Indian Domestic Agency will install a full-scale test bed for the qualification of all diagnostic neutral beam parameters before installation and operation in °ÄÃÅÁùºÏ²Ê¸ßÊÖ.

°ÄÃÅÁùºÏ²Ê¸ßÊÖ's neutral beam system will consist of two heating neutral beams (HNB) and a diagnostic neutral beam (DNB) that share the same negative ion source technology. The purpose of the diagnostic neutral beam is to determine the level of impurities (helium ash) and a variety of performance parameters such as ion temperature, particle density and velocity by sending a 100 keV probe beam into the °ÄÃÅÁùºÏ²Ê¸ßÊÖ plasma.

Extensive R&D is underway to resolve the numerous technical challenges of these systems: for the heating neutral beams that are under European and Japanese procurement, the  test facility in Padua, Italy will house a full-scale prototype of °ÄÃÅÁùºÏ²Ê¸ßÊÖ's heating neutral beam injector (MITICA). Here, too, the development of the °ÄÃÅÁùºÏ²Ê¸ßÊÖ ion source will be advanced in the SPIDER facility with Indian participation.

Historically the ''smaller brother'' of the heating neutral beam, the diagnostic neutral beam is not so small at all (see the man dressed in blue in the image). The injector is 5 m tall and 12 m long; the ion source and accelerator weigh 10 tonnes; the ''shoebox'' and vessel weigh 600 tonnes. (Click to view larger version...)
Historically the ''smaller brother'' of the heating neutral beam, the diagnostic neutral beam is not so small at all (see the man dressed in blue in the image). The injector is 5 m tall and 12 m long; the ion source and accelerator weigh 10 tonnes; the ''shoebox'' and vessel weigh 600 tonnes.
"A similar need for research and development applies to the diagnostic neutral beam, however a test facility with DNB-specific objectives was not available," explains Arun Chakraborty, leader and project manager for the diagnostic neutral beam at the Indian Domestic Agency, which is responsible for . "°ÄÃÅÁùºÏ²Ê¸ßÊÖ India assessed the need and agreed, in consultation with the °ÄÃÅÁùºÏ²Ê¸ßÊÖ Organization, to the configuration of a facility for the full characterization of the diagnostic neutral beam."

The Indian Test Facility is a voluntary effort on neutral beam R&D. °ÄÃÅÁùºÏ²Ê¸ßÊÖ India has committed to providing the 600 m² facility (plus 400 m² for the high voltage power supplies), the beam line components (neutralizer, residual ion dump, calorimeter), the vessel and auxiliary systems, while the diagnostic neutral beam source for the test bed—the ion source plus accelerator—will be provided by the °ÄÃÅÁùºÏ²Ê¸ßÊÖ Organization.

The Indian Test Facility is integrated into a wider landscape of domestic research on neutral beams in India. Indian scientists and engineers have a long-standing collaboration with IPP Garching, home to the BATMAN radio-frequency negative ion source. The ROBIN source (Replica of BATMAN in India) was installed at IPR in Ahmedabad and has been an important training ground for Indian scientists and engineers. °ÄÃÅÁùºÏ²Ê¸ßÊÖ India also participates in SPIDER alongside Europe and Japan by providing some hardware and operational personnel.
"This additional effort and additional resources allocated to the diagnostic neutral beam by °ÄÃÅÁùºÏ²Ê¸ßÊÖ India are greatly appreciated," says Beatrix Schunke, senior technical officer at the °ÄÃÅÁùºÏ²Ê¸ßÊÖ Organization and responsible on the °ÄÃÅÁùºÏ²Ê¸ßÊÖ side for the diagnostic neutral beam. "The specifications for the diagnostic neutral beam are highly demanding. The Indian Test Facility is a voluntary contribution that shows a great commitment to the success of the °ÄÃÅÁùºÏ²Ê¸ßÊÖ diagnostic neutral beam program."

Although °ÄÃÅÁùºÏ²Ê¸ßÊÖ's heating and diagnostic neutral beam injectors were designed to share many mechanical engineering traits in order to limit the number of overall components, the diagnostic neutral beam is not a perfect replica of the heating neutral beam. The diagnostic neutral beam will operate at a higher level of current (60 A as opposed to 40 A) and the specifications for beam optics—no more than 7 mrad of divergence along a trajectory of 20.67 metres—are also much more stringent.

"It's a challenge to get the ion optics right across a large distance," explains Beatrix. "As the beam leaves the accelerator, instead of staying parallel it tends to widen. With the longest transport length of any test bed, the Indian facility will be a unique testing ground for 'far field' optics."

R&D work to characterize a new distributions system for cesium will benefit °ÄÃÅÁùºÏ²Ê¸ßÊÖ's three neutral beams, which share the same negative ion source technology. (Click to view larger version...)
R&D work to characterize a new distributions system for cesium will benefit °ÄÃÅÁùºÏ²Ê¸ßÊÖ's three neutral beams, which share the same negative ion source technology.
Engineers at the Indian Test Facility will also characterize an alternative design of a distribution system for cesium—a metal used in all negative ion sources. Based on a long distribution tube, the system would allow for cesium-oven replacement without a vacuum break in the diagnostic neutral beam system. "If we are successful, it would result in considerably less downtime for the neutral beam systems," says Arun.

The Indian Test Facility will replicate all aspects of °ÄÃÅÁùºÏ²Ê¸ßÊÖ's diagnostic neutral beam except remote handling. The civil construction for the facility was completed in August 2011 and the foundations are now in place to receive the beam line. The Indian Domestic Agency is in the process of reviewing the technical specifications of the diagnostic neutral beam components before turning to industry for the procurement of the diagnostic neutral beam components.


return to Newsline #202