°ÄÃÅÁùºÏ²Ê¸ßÊÖ

Subscribe options

Select your newsletters:

Please enter your email address:

@

Your email address will only be used for the purpose of sending you the °ÄÃÅÁùºÏ²Ê¸ßÊÖ Organization publication(s) that you have requested. °ÄÃÅÁùºÏ²Ê¸ßÊÖ Organization will not transfer your email address or other personal data to any other party or use it for commercial purposes.

If you change your mind, you can easily unsubscribe by clicking the unsubscribe option at the bottom of an email you've received from °ÄÃÅÁùºÏ²Ê¸ßÊÖ Organization.

For more information, see our Privacy policy.

News & Media

Latest °ÄÃÅÁùºÏ²Ê¸ßÊÖ Newsline

  • Fusion supply chain | A glimpse into the future for commercial fusion reactors

    Most of the USD 7 billion in investment in private fusion initiatives has gone to companies that are building devices from the ground up. But recently, another [...]

    Read more

  • Outreach | °ÄÃÅÁùºÏ²Ê¸ßÊÖ @ October science festivals

    Every October, before schools pause for two weeks of holiday, towns and cities in France open their municipal spaces to scientific experts of all stripes who ar [...]

    Read more

  • Image of the week | °ÄÃÅÁùºÏ²Ê¸ßÊÖ Director-General visits Russia

    The °ÄÃÅÁùºÏ²Ê¸ßÊÖ Director-General was in Russia last week, meeting with stakeholders and holding technical meetings with colleagues in Moscow and Saint Petersburg. As [...]

    Read more

  • Image of the Week | Sector 5 is on its way

    The first vacuum vessel sector produced in Europe travelled last week between Monfalcone, Italy, and the French port of Fos-sur-Mer. The 440-tonne component had [...]

    Read more

  • Anniversary | °ÄÃÅÁùºÏ²Ê¸ßÊÖ Document Management system turns 20

    Whatever its nature, every large project generates huge numbers of documents. And when project collaborators operate from different countries, as was the case f [...]

    Read more

Of Interest

See archived entries

Gyrotrons

India successfully demonstrates °ÄÃÅÁùºÏ²Ê¸ßÊÖ power and pulse requirements

As a part of its in-kind commitments to the project, °ÄÃÅÁùºÏ²Ê¸ßÊÖ India will deliver two radio-frequency-based power sources (or "gyrotrons") with state-of-the-art specifications (170 GHz, 1MW, up to 3600 s), as wells as four main high voltage power supplies (6MW, 55kV each) for electron cyclotron resonance heating. The deliverables also include the associated auxiliaries and a demonstration of complete system performance at the °ÄÃÅÁùºÏ²Ê¸ßÊÖ site. One of the challenges of these complex high-power radio frequency systems is to establish integrated performance that is safe, reliable and easily repeatable despite working in a harsh electromagnetic environment.

The °ÄÃÅÁùºÏ²Ê¸ßÊÖ India Gyrotron Test Facility has been used to successfully carry out the site acceptance of a test gyrotron to °ÄÃÅÁùºÏ²Ê¸ßÊÖ power and pulse requirements. This significant achievement also confirms the successful commissioning of the megawatt-class, continuous wave test facility and validates the various auxiliary systems and their integrated performance. (Click to view larger version...)
The °ÄÃÅÁùºÏ²Ê¸ßÊÖ India Gyrotron Test Facility has been used to successfully carry out the site acceptance of a test gyrotron to °ÄÃÅÁùºÏ²Ê¸ßÊÖ power and pulse requirements. This significant achievement also confirms the successful commissioning of the megawatt-class, continuous wave test facility and validates the various auxiliary systems and their integrated performance.
In order to validate and demonstrate the required integrated system performance, a megawatt (MW), continuous-wave-class Gyrotron Test Facility (IIGTF) has been developed at °ÄÃÅÁùºÏ²Ê¸ßÊÖ India. The facility offers all the necessary auxiliary systems and services such as high-voltage and low-voltage power supplies; control, monitoring and protection systems; radio frequency diagnostic systems; cooling; and vacuum services. (These systems also serve as functional templates for actual °ÄÃÅÁùºÏ²Ê¸ßÊÖ deliveries.) A test gyrotron with °ÄÃÅÁùºÏ²Ê¸ßÊÖ-relevant specifications, along with a set of waveguide components including dummy loads, has been procured from M/s. GYCOM Russia and fully integrated with the test facility.

Extensive testing and validation of all interfaces was performed before the integrated testing. The main high-voltage power supply was validated for performance specifications including the Joule limit (wire burn test) to ensure the safety of the gyrotron during arcing.

The commissioned 6 MW main high-voltage power supply for the gyrotron cathode circuit at °ÄÃÅÁùºÏ²Ê¸ßÊÖ India. (Click to view larger version...)
The commissioned 6 MW main high-voltage power supply for the gyrotron cathode circuit at °ÄÃÅÁùºÏ²Ê¸ßÊÖ India.
After the interface validation tests, the site acceptance tests of the test gyrotron were successfully completed at °ÄÃÅÁùºÏ²Ê¸ßÊÖ India. Output radio frequency power of 1MW at 170 GHz for 1000 s with radio frequency efficiency of about 50 percent was demonstrated during "power and pulse" tests, comprising five successful 1000-second pulses. Various detailed tests such as reliability tests (with a number of successive pulses of 500 s each) and power modulation tests up to 1kHz have also been performed. This significant achievement also confirms the successful commissioning of the megawatt-class, continuous wave Gyrotron Test Facility at °ÄÃÅÁùºÏ²Ê¸ßÊÖ India and validates the various auxiliary systems and their integrated performance.

Test facility specifications:
Full-scale main high-voltage power supply:
- ratings of 6MW, 55kV
- based on PSM topology
- very fast time dynamics
- configuration compatible with °ÄÃÅÁùºÏ²Ê¸ßÊÖ space and interface provisions
Anode power supply:
- ratings of 40 kV, 500 mA
- cost-effective
- developed using a COTS high-voltage power supply
- high voltage solid-state series switch to obtain fast time dynamics
Control system:
- a mix of custom designed and COTS products
- an operator-friendly software user interface for efficient control
- live monitoring of various field signals with fast (~µs) and slow (ms) protection interlocks
Various auxiliary power supplies to drive the magnetic coils and other sub-systems of the gyrotron
Active cooling water distribution system with industrial instrumentation for various flow parameters

Test gyrotron specifications:
Diode-type MIG gun with depressed collector configuration
Gyrotron tube:
- typical beam acceleration voltage of 72 kV
- about 43 A of beam current
- operating at a cavity magnetic field of about 6.62 T
Matching optic unit at the output of the gyrotron, coupling the radio frequency power into an evacuated corrugated waveguide line that could be terminated with either a continuous wave dummy load or with a short-pulse atmospheric dummy load by means of an SPDT waveguide switch